PlatformIndustriesStandardsPricingResources
Sign inCreate your workspace

The quality and operations platform for asset-intensive industries. QMS and ERP. One audit-ready backbone.

Product

  • Platform
  • Pricing
  • Resources
  • Documentation
  • Partners
  • Contact

Domains

  • Quality and compliance
  • Health, safety and environment
  • Manufacturing and operations
  • Lean and performance
  • Projects
  • Supply chain and warehouse
  • Sales and customers
  • Finance
  • People
  • Management and governance

Industries

  • Oil & Gas
  • Fabrication & Manufacturing
  • Coating & Painting
  • Civil & Construction
  • TPI Agencies

Standards

  • ISO 9001 · 14001 · 45001
  • IATF 16949 · VDA 6.3
  • ASME
  • SAES / AGES · NORSOK
  • ZATCA · PINT AE
  • Peppol BIS 3.0

© 2026 Enspekt. All rights reserved.

PrivacyTermsTrust and securityLinkedIn (opens in a new tab)

Standards

What Enspekt supports, and how far.

Every standard below is marked with what is built today, what is partly built, and what is only a checklist or template. None of it is a certification claim.

How to read the status

Built
A working feature for the method or format.
Available now
Works today for the part of the standard the line names.
Checklists and templates
Seeded checklists you activate and edit. Not a separate feature.

Quality and automotive

  • ISO 9001:2015

    Checklists and templates

    Clause 4 to 10 system audit checklist, two inspection and test plan templates, and NCR, CAPA, document control and management review modules. It supports your quality system; it does not certify it.

  • IATF 16949

    Available now

    APQP, PPAP, FMEA, MSA, SPC and control plan modules, and an audit checklist for the clauses IATF adds to ISO 9001. Use it with the ISO 9001 checklist; it is not a complete audit on its own.

  • VDA 6.3

    Available now

    A process audit checklist for elements P4 and P6, with 34 questions and star-question flags. Items are scored 1 to 5; the VDA 0 to 10 scale and the A/B/C grade are not built.

  • VDA 5

    Available now

    A Cg/Cgk gage capability study; bias, linearity, stability and attribute studies; and a measurement uncertainty record for each study. You list the contributions (or add values from your other finished studies on the same gauge, or from the gauge's calibration certificate), give correlations where contributions are not independent, enter the coverage factor and your own limits, and it reports the expanded uncertainty, the effective degrees of freedom, its share of the tolerance and an index, with a short PDF, a register across studies, a sign-off step and a flag when a copied value has since changed. The limits are always yours: none is supplied. It does not decide which contributions apply to your measurement, and it is not a statement of conformity to any standard.

  • AIAG PPAP

    Built

    All 18 PPAP elements, with the elements required at each submission level.

  • AIAG-VDA FMEA

    Built

    The AIAG-VDA 2019 method with Action Priority, plus the earlier RPN method.

  • AIAG MSA

    Built

    Gage R&R, bias, linearity, stability, attribute and Cg/Cgk studies.

  • AS9102

    Available now

    AS9102 is the default standard on first article records. There is no AS9100 clause checklist.

  • ISO 17025

    Available now

    Calibration records carry uncertainty budgets: the inputs, their distributions, sensitivities and any correlations combine into an expanded uncertainty that prints on the certificate, in English, French or Arabic. You choose the coverage factor; a simulation check and a suggestion from the effective degrees of freedom are offered, never applied for you. A budget is locked once its certificate is issued, and changed only by a corrected copy. You can enter your own accreditation details and scope register, which Enspekt stores and does not verify; the clause checklist is an empty shell you load from your own licensed copy. A certificate is not an accredited one unless you entered accreditation that is in date, and then it is printed as your own declaration.

Oil, gas and industrial inspection

  • SAES

    Checklists and templates

    A SAES-W-011 welding inspection and test plan (20 checkpoints) and a SAES-H-001 coating plan.

  • ASME B31.3

    Checklists and templates

    An ASME B31.3 process piping plan with hold and witness points (22 checkpoints).

  • NORSOK M-501 / M-601

    Checklists and templates

    A NORSOK M-501 coating plan (30 checkpoints) and an M-601 welding plan.

Safety and environment

  • ISO 45001:2018

    Available now

    A clause-by-clause audit checklist, an incident register, job safety analysis and permit to work.

  • ISO 14001:2015

    Available now

    An aspects and impacts register, a legal register, environmental records and a clause 4 to 10 audit checklist.

  • OSHA recordkeeping

    Available now

    An OSHA-recordable flag and a recordkeeping section on each incident. The Form 300 log, the Form 300A summary and a Form 301 for each case are generated as PDFs, in an equivalent layout rather than OSHA's own. Enspekt does not submit them to OSHA.

  • GHG Protocol

    Available now

    A Scope 1, 2 and 3 emission log with factors and a CO2e calculation. It is not a verified inventory.

Finance and e-invoicing

  • IFRS

    Available now

    An IFRS-aligned chart of accounts, an IFRS 16 lease register, IFRS 15 over-time revenue and IFRS 9 expected credit losses.

  • ZATCA

    Available now

    Works today: customer invoices and credit and debit notes as signed UBL 2.1 XML with the QR code, checked against ZATCA's rules before posting. Phase 2 integration with ZATCA Fatoora (onboarding, clearance and reporting) is in progress and not yet proven with a live taxpayer. Point of sale: a till onboarded as its own ZATCA unit signs each sale as a simplified tax invoice for reporting, also not yet proven with a live taxpayer; other tills print the Phase 1 QR.

  • PINT AE

    Available now

    Builds and validates PINT AE invoices and sends them through your accredited access service provider. Enspekt does not report to the FTA itself.

  • Peppol BIS 3.0

    Available now

    EN 16931 and Peppol BIS 3.0 rules, outbound and inbound. Delivery needs a gateway you configure.

  • ETA

    Built

    Builds, validates, signs, submits and refreshes status. It uses your own ETA credentials and signing service.

  • SEPA pain.001

    Built

    pain.001.001.09 credit transfer files for supplier payments. Enspekt writes the file; you send it to your bank.

  • eCDF

    Available now

    Generates the eCDF files for Luxembourg returns. You upload them yourself with your LuxTrust credential.

Signatures and records

  • PAdES

    Built

    Sealed PDFs are PAdES-B-T when a time-stamp authority is configured and PAdES-B-B otherwise. They are not eIDAS qualified signatures.

  • 21 CFR Part 11

    Available now

    E-signatures that ask for the password again, with an audit trail. This is not a claim of Part 11 compliance.

Not built yet

These names appear around the industry, so we say plainly where we stand.

API Q1 / Q2
Empty shells only: an audit checklist and an inspection plan outline with a file import. The standards are licensed, so none of their items are included; you load them from your own licensed copy.
ISO 17020
Not built as a feature. Supporting records exist: an inspector authorisation register by inspection type, an impartiality declaration per inspection job, and the instruments used, frozen when the job is submitted. They are internal records, not an accreditation and not a claim of conformity.
NACE
No NACE or AMPP practice is built in. There is a coating inspection record (ambient conditions, film thickness readings, other measurements you define, files, a link to an NCR, the gauge used, a hold point before sign-off) with limits you enter from your own specification. It is not a claim of conformity to NACE or AMPP practices.

Enspekt supports how you work to these standards. It does not certify your company, and each standard belongs to the body that publishes it.

Bring your plant onto one record.

Create your workspace and switch on the modules you need. Every workspace is reviewed before activation.

Create your workspaceTalk to us